SOLARGE

Callus

Barcelona, Spain

Multi family house | 13 sqm installation

 


Summary

The present assessment deals with a solar thermal system to be installed on two residential buildings in Callus, Spain.
The solar thermal installation proposed covers the mandatory solar fraction of 50 % for hot tap water in the zone III in Spain, according to the new Spanish building code (CTE). Its size has been estimated with the SOLARGE tool.
A back-up heating system is needed to ensure the availability of hot tap water during the whole year. The reduction of final energy has been estimated from the energy consumption of a natural gas boiler (η=0,7) for hot water preparation.
Additional building information has been summarised on the Checklist for the estimation of technical parameters of solar thermal installations designed within the SOLARGE framework.


 


Building

Type of building

Multi family house

Number of dwellings, floors

2 buildings
41 users

Year of construction

2008

Total effective area (heated)

not available 

Hot tap water consumption

329 m3/a

Whole energy consumption for heating purpose (present situation)

./.


Proposed CSTS (main variant)

Type of collectors

Flat plate collectors

Thermal power

9.1 kWtherm.

Aperture area of collectors*)

13 m2

Buffer storage

1.0 m3

Hot tap water storage

- 

Total capacity of boilers

-

Type of hot tap water heating

Natural gas

Type of heating system

./.


Estimated Costs

Total cost solar system

not available

Cost of the CSTS/gross area of collectors

not available 

Available Subsidies

not available


Predicted System Output

Output of solar heat

10,829 kWh/a

Reduction of final energy

15,470 kWh/a

CO2-emissions avoided

3.66 t CO2/a


*) Aperture area = light transmitting area of the front glass

 



Assessment by

Ecofys SL
Paseo del Ferrocarril, 335, 4o-1a
08860 Castelldefels (Barcelona), Spain
Phone: +34 93 6455-458
Fax: +34 93 6455-184
info(at)ecofys.es
www.ecofys.es

 

Downloads

SOLARGE_building_assessment_summary_callus_en.pdf

This assessment summary (English)

487 K

SOLARGE_building_assessment_report_callus_es.pdf

Detailed assessment report, 5 pages (Spanish)

176 K