”Sundparken” Solvarmeanlæg, Helsingør boligselskab

Elsinore, Helsingør, Denmark

Multi-family house | 336 sqm installation

Data acquisition is still in process!

 


Project summary · Technical description · Financing · Development · Downloads

Project Summary

Description

The tenants initiated the installation of the CSTS and the motivator was the board of the association. The CSTS consist of flat plate collector in 2-part orientation, one field towards the east and one m2 field towards the west. In the basement of the building is located the heating central consisting of heat exchangers and storage tank.
The solar thermal system was made as a demonstration project and consequently the price of the plant reflects this issue. It is difficult to distinguish and break down the costs.
The solar loop pipes are installed inside the cavity wall insulation of a new exterior wall made on the gable, which at the same time have reduced the heat loss from the building. The building is at the same time refurbished with a new top roof layer of the type “Decra”. The insulation in the attic was increased to 300 mm. New thermal windows are installed everywhere.
The CSTS is only for hot tap water. The boiler station in the basement has been renovated at the same time.
There are great possibilities for enlargement of the solar collector area for space heating but for the moment the return temperature from the radiator system is considered to be too high.




 


Building

Type of building

Multi-family house

Number of users / dwellings, floors

850 users
425 dwellings
2/3/4 floors + basement

Year of construction

1960–65

Total effective area (heated)

39,066 m2

Hot tap water consumption (measured/estimated)

15,330 m3/a (measured)

Whole energy consumption for heating purpose after CSTS implementation

4,000,000 kWh/a


System engineering

Year of construction of CSTS

2000

Type of collectors

Flat plate collectors

Thermal power

235 kWtherm.

Aperture area of collectors*)

336 m2

Buffer storage

10.0 m3

Hot tap water storage

6.0 m3

Total capacity of boilers with energy source

3,680 kW, district heating

Type of hot tap water heating

Centralised

Type of heating system

Centralised


Costs

Total cost solar system

240,000 Euro

Cost of the CSTS / gross area of collectors

714 Euro/m2

Subsidies

13 %


Output

Output of solar heat**)

123,000 kWh/a

Reduction of final energy***)

123,000 kWh/a

CO2-emissions avoided

not avialable

Solar performance guarantee

No

*) Aperture area = light transmitting area of the front glass
**) measured, between storage and piping to taps (solar system output)
***) related to the measured output mentioned before

 

 


Poul Hansen, Sundparken Chairman


 

 


Owner

Helsingør Boligselskab
Poul Hansen (chairman)
Kongedammen 34
3000 Elsinore
Phone: +45 49 2128-61
Fax: +45 49 2128-91
sundparken(at)stofanet.dk
www.sundparken.dk


Operator

See owner

Top of page Project summary · Technical description · Financing · Development · Downloads

Technical description

 


Description of the CSTS

Year of construction of CSTS

2000

Thermal power

235 kWtherm.

Gross area of collectors

336 m2

Aperture area of collectors

336 m2 

Type of collectors

Flat plate collectors

Type of assembly

Roof top

Orientation of collectors

East (-90°), West (+90°)

Inclination angle to horizon

15°

Freezing protection

Glycol

Overheating protection

Drain back

Operation mode

Variable

Use of CSTS for

Hot tap water heating

Buffer storage

10.0 m3, one storage tank with SOLVIS stratification system

Hot tap water storage

6.0 m3 (2 × 3 m3), “after“ buffer storage

Control of backup-system / CSTS

Separated control ("Trend")


Hot tap water system

Type of hot water heating

Centralised

Recirculation system

Yes

For decentralised systems:
The installation on the consumer site

./.

Size of storage for hot tap water

6.0 m3

Specification (if necessary)

./.


Space heating system

Type of heating system

Centralised

Number of boilers

2 heat exchangers

Total capacity (power output) of boilers

3,000kW

Capacity of each boiler (year of construction)

all: 1,500 kW

Energy source

District heating

Type of boiler system

Standard


Type of operation

Operator of the CSTS system

Self-operation

CSTS monitoring

Yes: output of solar heat, total water consumption. Temperatures, flow, production etc. The Association is checking and a consulting company have online internet access to the computer.

Data accessible via internet

Yes: consultant only

Scientific monitoring / follow up

Yes

Maintenance contract

No

Visualisation of the solar heat output

No


Yield of CSTS plant

Output of solar heat

123,000 kWh/a

Origin of data

Measured

Measuring point

Between collector and storage, between storage and piping to taps, cold water for hot water

Reduction of final energy

123,000 kWh/a

Origin of data

Computer

Solar performance guarantee

No


Heat consumption

Whole energy consumption for heating purposes after CSTS implementation

4,000,000 kWh/a

Origin of data

Measured

Energy used for

Hot tap water heating, space heating

Whole energy consumption for heating purposes before CSTS implementation

4,900,000 kWh/a

Total tap water consumption

38,880 m3/a

Hot tap water consumption

15,330 m3/a

Hot tap water temperature

55 °C

Cold water temperature

9 °

 

 


Summary

In year 2000 a 336 m2 solar domestic hot water system was built in Sundparken, Elsinore, Denmark.

The solar heating system is a low flow system with a 10,000 ltr. hot water tank. Due to the orientation of the buildings the CSTS is made as two separate plants with common storage. Half of the solar collectors (168 m2) are facing east, the other half of the solar collectors (168 m2) are facing west.

The collector tilt is 15° from horizontal for all collectors. Both the east-facing and the west-facing collectors have their own solar collector loop, circulation pump, external heat exchanger and control system.

The external heat exchangers are used to transfer the heat from the solar collector fluid to the domestic water. The domestic water is pumped from the bottom of the hot water tank to the heat exchangers and back to the hot water tank through stratification inlet pipes. The return flow from the DHW circulation pipe also enters the tank through stratification inlet pipes. The tank design ensures an excellent thermal stratification in the tank.

District Heating maintains the necessary set point temperature of the hot water via two other heat exchangers. The system also contains two 3 m3 tanks as DHW buffer. Further two heat exchangers are installed between the District heating system and the space heating system.



 



Top of page Project summary · Technical description · Financing · Development · Downloads

Financing and investment

Introduction

The project was mainly financed by own sources from the housing associations own revolving funds; a small loan and national subsidies and tax reduce.

 


 


Financing of the CSTS

Form of financing

Purchase

Distribution in percentage

33 %
Grants: 32,000 EUR
5%-low interest loan: 66,000 EUR (country building funds)
Tax credits: 10,000 EUR


Costs of solar materials

Total cost of solar system

240,000 Euro

Detailed costs for

Collectors

74,000 Euro

Elevation / mounting structure

7,00 Euro

Storage / heat exchanger

20,000 Euro

Backup heater

0 Euro (existing)

Control

7,000 Euro

Installation

98,000 Euro

Planning / Engineering

20,000 Euro

Others

14,000 Euro


Operation costs of heating system

Power cost for pumping

+100 Euro/a

Maintenance cost

+200 Euro/a

Monitoring cost

+10 Euro/a

Other operation cost

./. Euro/a

Total operation cost

+310 Euro/a

Or:
Increase of the operation cost after CSTS implementation

310 Euro/a

 

 

 



Top of page Project summary · Technical description · Financing · Development · Downloads

Development & experiences

Qualitative aspects of the CSTS

The Chairman of the association motivated the tenants to vote yes for the plant and consequently an increase in rent over a limited period of time and after a reduction.


Summary of experiences / Notices to the project performance

 

 


Experiences management

Experienced problems or failures?

No

Found solutions to these problems or failures?

./.


Financial effects / project performance

Project economically efficient?

Yes

Fiscal or other financial effects?

No

Effects on rental fees?

Yes: saving on the cost for District Heating, the energy and consequently the money saved is directly saved in the tenants heating bill.


Experiences technical staff

Experienced problems or failures?

No

Found solutions to these problems or failures?

./.

 

 


Engineering

 

Vagn Duer, Rådgivende Ingeniør A/S
Landsebakken 10
2840 Holte, Denmark
Phone:    +45 45 423568
Fax:    +45 45 410204
vagnduer(at)vagnduer.dk
www.vagnduer.dk

Top of page Project summary · Technical description · Financing · Development · Downloads

Downloads

SOLARGE_goodpractice_dk_sundparken.pdf

this datasheet in printable PDF-format

770 K

sundparken_scheme.pdf

the hydraulic scheme

70 K